01 Baseline Perimeter Demolition and Core Containment
The primary design challenge centered on separating the primary elevator lobby and executive restrooms from the upcoming structural slab cutouts. Before any demolition permits were issued, all existing interior demising walls and mechanical drops were assigned to an immutable "Existing" phase. Temporary one-hour fire partitions were then modeled in "Phase 1 - Demolition & Containment" with their Phase Demolished property set directly to "Phase 2 - Perimeter Buildout". This specific configuration ensured that temporary barriers automatically disappeared in downstream presentation sheets without requiring manual line hiding.
Standard view templates were applied across all demolition floor plans, utilizing graphic overrides that highlighted removed partitions in dashed halftone lines while rendering retained core elements in continuous neutral gray. By keeping the existing perimeter curtain wall untouched in the model schedule, the estimating team avoided mistaken demolition pricing for exterior glazing assemblies.
Never assign existing primary structural columns or core MEP risers to a temporary phase. Always keep them in the base "Existing" phase and use dedicated containment wall families to demarcate dusty construction envelopes.